1. Mount the LT25 securely to a stable, flat surface using the
mounting bracket with ¼” (6mm) max. diameter fastener.
2. Attach cable using the eyelet provided (M4, #8 screw or
3/16”pin)
Remove the four screws on encoder flange (use 5/32”
hex driver), rotate encoder in 90°increments and
tighten screws to approx. 13 in-lb.
Remove the four screws as shown with a PH-2
(Phillips) driver , reposition in 90°increments,
and tighten screws to approx. 13 in-lb.
 
  




 
!" #
$ $
Mounting
Bracket
Eyelet
Mounting
Holes (4)
Vista de pagina 0