Page 11 Inclinometer RS232 – Current Datasheet Version: 20130503
INCLINOMETER
RS232 – CURRENT
9 Commands in User Level
activate temporary polling
mode
the continuous sending of
angle values is stopped,
instructions can be sent to the
sensor
activate temporary continuous
mode
„X=vxx.xxx“, CR, LF,
„Y=vxx.xxx“, CR, LF,
„X= . . .
X angle in °
Y angle in °
with „±” = „+“ or „-“,
one string contains x and y
value
read angle values
at one-timeErreur ! Source
du renvoi introuvable.
„X=vxx.xxx“, CR, LF,
„Y=vxx.xxx“, CR, LF,
X angle in °
Y angle in ° with „±” = „+“ or „-“
switch to the setup level
3) 4)
„U“ means Sensor is at User
level
„S“ means Setup-level is
active,
with „x“ Output-Mode of
Sensors „U“ / „I“ / „P“ / „S“
1) In free running mode measurement data is continuously displayed. In query mode measurement and display is only once on
command.
2) After reset or new Power On after an interruption of power supply, the sensor will be in user-level again with the original setup or with
the setup changed in the setup level.
3) Only possible in query mode (=free running mode deactivated).
4) The Input of „prog“ must take place within 20 sec.